HVAC Service, Repair and Installation
Latest videos by @flotech_mechanical
-
– video
15 likes 1 comment 0 shares 1 save
Chilled Water Air Handler Replacement Shut down on a Friday, up and running by Sunday. Preparation is key - adds time to the job on the front end, but saves in the long run and keeps the customer happy. Circuit setter and 3-way valve to modulate flow. New QPac controller with ModBUS communication…
-
– video
10 likes 1 comment 0 shares 1 save
Troubleshooting using thermal imaging. It measures temperature difference - so we can see restrictions. This works on refrigerant systems, water systems, and air systems. Pumps increase pressure, not temperature. And they only pump water - not air. It’s as simple as priming a pump, make sure the…
-
– video
11 likes 2 comments 0 shares 0 saves
Chilled Water Work Shut down the building - added taps for temporary Chiller. Changed some AHU valves while the building was drained. We put in the work. The results speak for themselves. #chillers #welding #pipefitter
-
– video
53 likes 0 comments 3 shares 1 save
Air Cooled Chiller Installation With Built up Air Handler We installed the AHU, and piped in a temporary chiller waiting for the site Chiller. Landed all the equipment, piped in the Chiller and Buffer tank, and the runaround pumps. Running at 32 F with glycol. #chiller #hvac #Daikin #pipefitting
-
– video
20 likes 5 comments 0 shares 3 saves
Centrifugal Chiller Replacement - pulled out an old McQuay PEH , installed a new WMC. #Daikin #pipefitter #welding #chiller #gowiththeflow
-
– video
19 likes 0 comments 0 shares 2 saves
Small little Air Handler change out at a College. Small equipment, big standards. Do what you have to do to get it done #hvac #daikin #pipefitting #gowiththeflow
-
– video
32 likes 1 comment 0 shares 9 saves
Troubleshooting electrical issues Finding shorts, grounds, or voltage drops can be tricky Circuit breakers and fuses have Amp ratings to trip. This was rated for 3 A and constantly tripping. Customer just keeps resetting. Found control circuit pulling 3.6 A. Circuit breaker doing its job. Need…
-
– video
22 likes 0 comments 2 shares 0 saves
CWP Strainers Customers don’t care about efficiency, it’s ALL visual. Keeping a clean work area, van, clothes, and mechanical room - makes all the difference. We cut in and added isolation valves, and installed y-strainers before the pumps. Be proud of what you do #pipefitter #pumps #hvac
-
– video
751 likes 56 comments 38 shares 85 saves
Step by Step: AHU Bearing Replacement 1. Shut down unit, LOTO 2. Remove belts if necessary 3. Remove pulley bolts, use for jacking pulley 4. Clean shaft and pull off hub and pulley 5. Clean shaft some more 6. Remove bearing housing - pillow block, flange mounted, all the same. Use heat for…
-
– video
30 likes 1 comment 2 shares 1 save
This trade is the best in the world. Diverse, challenging, and rewarding 🩵 #hvac #gowiththeflo #service #chillers
-
– video
36 likes 1 comment 0 shares 1 save
Union vs Non-Union Watch til the end to see the difference #pipefitting #daikin #gowiththeflo
-
– video
49 likes 1 comment 3 shares 1 save
-
– video
188 likes 15 comments 6 shares 9 saves
-
– video
550 likes 11 comments 8 shares 50 saves
YMC2 Chiller Install… #york #chiller #hvac #pipefitter
-
– video
154 likes 4 comments 2 shares 20 saves
Troubleshooting Chiller Issues: Chiller tripping on High Discharge Pressure and Surging Faults On constant flow machines, most are designed for 10 F on evaporator and condenser. Capacity should equal Delta T 1. Measure actual pressure drop vs design 2. Confirm pressure transducers and temperature…
-
– video
375 likes 17 comments 10 shares 36 saves
-
– video
898 likes 3 comments 57 shares 436 saves
Testing contactor coils - or any coils If you measure: 24 V @ coil - pulls in: coil good 24 V @ coil - doesn’t pull in: coil bad 0 V @ coil - make the common How? Hot lead to hot wire, neg lead to common (panel or ground): 24 V - break in common 0 V - no voltage Measuring less than 24 V? Likely a…
-
– video
34 likes 8 comments 1 share 7 saves
York Liquid Level Sensor Replacement… Sensor wasn’t reading a level, confirmed refrigerant presence. #hvac #chiller #york #yvwa #hvacservice
-
– video
32 likes 2 comments 1 share 9 saves
How to Install VFD 1. Measure voltage supply; confirm motor integrity 2. Measure all control voltage wires - external voltage, open or closed safeties, relays, speed reference 3. Identify control wire purpose using IOM or wire diagram of existing VFD to connect properly to new 4. Remove all…
-
– video
17 likes 1 comment 0 shares 1 save
Details matter. A clean coil looks and works much better. #hvac #coilclean #nasty
-
– video
20 likes 1 comment 1 share 2 saves
25 HP Motor Replacement. Stop using wire nuts on big motors. Alignment and tight electrical connections prevent premature failures #hvacservice #motor #solo
-
– video
22 likes 1 comment 0 shares 1 save
-
– video
17 likes 2 comments 0 shares 3 saves
Cooling Tower Assembly: Replacing bearings, fan, pulleys and motor. #coolingtower #hvac #retro #bearings
-
– video
15 likes 0 comments 0 shares 0 saves
There are a lot of things that can be fixed… not this #compressor #blowout #hvac #york
-
– video
30 likes 0 comments 1 share 11 saves
Sensing Bulb Placement: 1) Should be horizontal - IF, vertical, cap tube on top 2) 10-2 or at 12 depending on pipe size 3) Doesn’t measure anything if it’s not touching pipe #hvac #hvacservice #txv #themoreyouknow
-
– video
28 likes 3 comments 4 shares 8 saves
-
– video
9 likes 0 comments 0 shares 1 save
Coil cleanings - NEEDED NOT RECOMMENDED; makes a huge difference #coilcleaning #hvac #hvacservice #dirty
-
– video
28 likes 0 comments 4 shares 7 saves
Bad vibrations - bad bearings and bad blower wheel. Replaced and cleaned #hvac #hvacservice #motor #vibracion
-
– video
27 likes 1 comment 3 shares 4 saves
Condenser Fan Motor Replacement - simple but easy mistakes can be made #hvac #hvacservice #cfm #motor
-
– video
49 likes 2 comments 2 shares 17 saves
Troubleshooting 3-Phase motor: #hvacservice #hvac #troubleshooting #motor #howtotroubleshoot
Showing 30 of 32 videos
Load more videosExplore & export videos
Uses the videos loaded on this page. Load more to include older ones.
Videos by month
@flotech_mechanical TikTok stats
@flotech_mechanical has 1,125 TikTok followers as of . That is about 1.1K followers.
- Followers
- 1,125
- Likes
- 3,551
- Videos
- 32
- Likes per video
- 111
- Average video length
- 0:22
- Median per post
- 1.4K views · 29 likes · 1 comment · 1 share · 3 saves
- Average engagement per view - follower
- 3.1% - 0.11
- Average views per follower
- 3.66
- Most viewed recent posts
- “Step by Step: AHU Bearing Replacement 1. Shut down unit…” · 30.4K views · 751 likes · 56 comments ·
- “Testing contactor coils - or any coils If you measure: 24…” · 28.6K views · 898 likes · 3 comments ·
- “YMC2 Chiller Install…” · 11.2K views · 550 likes · 11 comments ·
- Last post
- (8 days before this check)
- Posting rate
- about 11.9 posts a year
- TikTok content labels
- Work & Jobs (27 of 28 posts), Daily Life (27 of 28 posts)
- Hashtags used most
- #hvac (25), #hvacservice (8), #daikin (7), #chiller (6), #chillers (5)
@flotech_mechanical follower history
Followers on the left axis, likes on the right. Recording started on ; each day this profile is refreshed adds a point. How the follower history is recorded
About @flotech_mechanical
Account created